Effects of Resin Particle Size and Solution Temperature on SuperLig(R) 644 Resin Performance with AN-105 Simulate
The performance of the SuperLig(R) 644 resin loading and elution was evaluated at 25, 35, and 45 degree C using a single-column containing 2.25 g of oven-dry, hydrogen form of SuperLig(R) 664 resin. A simulated Envelope A solution was used to mimic the composition of low-activity waste solution from Tank 241-AN-105 supernate in the Hanford Site waste tank. The simulant was spiked with small quantities of trace metals (cadmium, chromium, iron, and lead) to evaluate the effects of these metals on cesium sorption. The results from column tests performed at 25, 35, and 45 degree C showed that more than 100 BVs of simulated Envelope A solution could be processed at each temperature before 50 percent breakthrough of the cesium occurred.
- Research Organization:
- Savannah River Site (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 812406
- Report Number(s):
- WSRC-TR-2001-00606
- Country of Publication:
- United States
- Language:
- English
Similar Records
The Effect of Temperature of SuperLig (R) 644 Cesium Removal from Simulated Hanford Tank Waste Supernate
SuperLig(R) 644 Resin Accelerated Aging Study
Sorption of Cesium From Aqueous Waste Solution on SuperLig 644 Resin
Journal Article
·
Tue Dec 03 23:00:00 EST 2002
· Journal Radioanalytical and Nuclear Chemistry
·
OSTI ID:805618
SuperLig(R) 644 Resin Accelerated Aging Study
Journal Article
·
Tue Dec 03 23:00:00 EST 2002
· Journal Radioanalytical and Nuclear Chemistry
·
OSTI ID:805617
Sorption of Cesium From Aqueous Waste Solution on SuperLig 644 Resin
Journal Article
·
Tue Aug 24 00:00:00 EDT 2004
· Industrial & Engineering Chemistry
·
OSTI ID:834244