Thermal Analysis and Test Results for the Overpack of a Typical Radioactive Materials Package
Conference
·
OSTI ID:810795
In the course of the development and certification of the 9975 Package, extensive thermal analyses were performed and the package subjected to the regulatory HAC thermal test. The results of the thermal analysis and materials tests of the cane fiberboard overpack material were evaluated in comparison with the package HAC thermal test results. The evaluation confirmed that the thermal analysis correctly predicted the performance of the 9975 in the HAC fire test. The post test examination revealed that the heat affected region of the Celotex(R) overpack correlated well with the calculated temperature distribution
- Research Organization:
- Savannah River Site (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 810795
- Report Number(s):
- WSRC-MS-2003-00300
- Country of Publication:
- United States
- Language:
- English
Similar Records
The Effect of an Annular Celotex(r) Gap on the 9975 Package
WHITE PAPER: DEMONSTRATION OF EQUIVALENCY OF CANE AND SOFTWOOD BASED CELOTEX FOR 9975 PACKAGING
DEMONSTRATION OF EQUIVALENCY OF CANE AND SOFTWOOD BASED CELOTEX FOR MODEL 9975 SHIPPING PACKAGES
Conference
·
Mon Feb 19 23:00:00 EST 2001
·
OSTI ID:775075
WHITE PAPER: DEMONSTRATION OF EQUIVALENCY OF CANE AND SOFTWOOD BASED CELOTEX FOR 9975 PACKAGING
Technical Report
·
Mon Nov 19 23:00:00 EST 2007
·
OSTI ID:920380
DEMONSTRATION OF EQUIVALENCY OF CANE AND SOFTWOOD BASED CELOTEX FOR MODEL 9975 SHIPPING PACKAGES
Conference
·
Tue May 27 00:00:00 EDT 2008
·
OSTI ID:932222