Measured longitudinal beam impedance of a Tevatron separator

Technical Report ·
DOI:https://doi.org/10.2172/805558· OSTI ID:805558

Twenty two separators are currently installed in the Tevatron. The longitudinal impedance of one of these devices was recently measured with a stretched wire. The stretched wire technique can only measure impedance below the cutoff frequency (500MHz). The geometry of a separator is similar to an un-terminated stripline beam position detector. The separator plates occupy a 13.5'' ID vacuum tank, are 101'' long, 7.8'' wide, and have a 2'' gap between them. The differential characteristic impedance between the plates is estimated to be 81 {Gamma} and the common mode impedance plate to ground is about 42 {Gamma}.

Research Organization:
Fermi National Accelerator Lab., Batavia, IL (US)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
805558
Report Number(s):
FERMILAB-TM-2194
Country of Publication:
United States
Language:
English