Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Analysis of Waste Leak and Toxic Chemical Release Accidents from Waste Feed Delivery (WFD) Diluent System

Technical Report ·
DOI:https://doi.org/10.2172/804845· OSTI ID:804845
Radiological and toxicological consequences are calculated for 4 postulated accidents involving the Waste Feed Delivery (WFD) diluent addition systems. Consequences for the onsite and offsite receptor are calculated. This analysis contains technical information used to determine the accident consequences for the River Protection Project (RPP) Final Safety Analysis Report (FSAR).
Research Organization:
FFS (US)
Sponsoring Organization:
ENVIRONMENTAL MANAGEMENT (US)
DOE Contract Number:
AC27-99RL14047
OSTI ID:
804845
Report Number(s):
RPP-5098, Rev.1; ECN-660928
Country of Publication:
United States