Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Mathematical Aspects of Unique Signal Assessment

Technical Report ·
DOI:https://doi.org/10.2172/800955· OSTI ID:800955

This report is a supplement to ''The Unique Signal Concept for Detonation Safety in Nuclear Weapons,'' SAND91-1269, which provides a prerequisite fundamental background on the unique signal (UQS) concept. The UQS is one of the key constituents of Enhanced Nuclear Detonation Safety (ENDS), as outlined in Section 1 of that report. There have been many documents written over the past quarter of a century describing various aspects of the UQS, but none of these emphasized the mathematical approaches that help explain why the UQS is effective in resisting inadvertent pre-arming, even in abnormal environments and how UQS implementations can be quantitatively assessed. The intent of this report is to describe various pertinent mathematical methodologies (many of which have not been previously reported) without duplicating, any more than necessary, background information available in other reports. Mathematical UQS analysis is needed because of quantitative requirements associated with ENDS, and because limited comparisons of various implementation approaches can be quantified under mathematical modeling assumptions. Some of the mathematics-based results shown in this report are presented to explain: (1) The reasons that the UQS methodology can provide greater protection against accident environments than could combinational techniques (Sections 2.1 through 2.4); (2) The reason that the probability of inadvertently duplicating a UQS comprising n bivalued events cannot be estimated as low as (1/2) inches (Section 2.4); (3) The value of, and the Sandia National Laboratories policy on independent sequential communication of UQS events (Section 3.4); and (4) The care that must be exercised if any signal processing is necessary (Section 4). There are also numerous examples (e.g., in Appendices A and B) of ill-advised deviations from UQS methodology that can seriously degrade safety. These examples help demonstrate that the UQS methodology should not be compromised.

Research Organization:
Sandia National Labs., Albuquerque, NM (US); Sandia National Labs., Livermore, CA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
800955
Report Number(s):
SAND2002-1306
Country of Publication:
United States
Language:
English

Similar Records

Unique Signal mathematical analysis task group FY03 status report.
Technical Report · Sun Nov 30 23:00:00 EST 2003 · OSTI ID:918228

The unique signal concept for detonation safety in nuclear weapons
Technical Report · Tue Jun 01 00:00:00 EDT 1993 · OSTI ID:10177801

Indirect Lightning Safety Assessment Methodology
Technical Report · Fri Apr 24 00:00:00 EDT 2009 · OSTI ID:959070