The Run IIb upgrade of the CDF silicon detectors
Conference
·
OSTI ID:799177
- Fermilab
A substantial portion of the Run IIa silicon detectors of the CDF experiment will not perform adequately for the duration of Run IIb (15 fb{sup -1}) because of radiation damage. The Silicon Vertex Detector (SVX-II) and Layer 00 will be fully replaced at the end of Run IIa. The Run IIb silicon tracker has a baseline design that safely achieves the required radiation tolerance by using single sided sensors that are actively cooled. The new Run IIb castellated layout contains more silicon surface area and has a more uniform radial distribution. It minimizes the number of hybrid and sensor varieties providing quick construction and assembly. The total mass in the tracking volume is reduced by eliminating unnecessary the passive material from the CDF volume.
- Research Organization:
- Fermi National Accelerator Lab., Batavia, IL (US)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 799177
- Report Number(s):
- FERMILAB-Conf-02/164-E
- Country of Publication:
- United States
- Language:
- English