Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

MEASUREMENT OF TRANSVERSE BUNCH SIZE BLOW-UP DUE TO THE ELECTRON CLOUD INSTABILITY AT PEP-II

Technical Report ·
DOI:https://doi.org/10.2172/799071· OSTI ID:799071
The electron cloud instability at PEP-II is responsible for enlargement of the transverse bunch size for positron bunches at high current. Presented in this paper are the measurements of transverse beam blow-up taken by a two nanosecond-gated camera. The measurements point out that a current-ramp, mini-gaps between trains, and arc solenoid windings help reduce the positron bunch size blow-up due to the electron cloud instability.
Research Organization:
Stanford Linear Accelerator Center, Menlo Park, CA (US)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
799071
Report Number(s):
SLAC-PUB-9222
Country of Publication:
United States