COUPLING MEASUREMENT AND CORRECTION AT RHIC.
Coupling correction at RHIC has been operationally achieved through a two-step process: using local triplet skew quadrupoles to compensate coupling corn rolled low-beta triplet quadrupoles, and minimizing the tune separation and residual coupling with orthogonal global skew quadrupole families. An application has been developed for global correction that allows skew quadrupole tuning and tune display with a choice of different tune measurement techniques, including tune-meter, Schottky and phase lock loop (PLL). Coupling effects have been analysed by using 1024-turn (TBT) information from the beam position monitor (BPM) system. These data allow the reconstruction of the off-diagonal terms of the transfer matrix, a measure of global coupling. At both injection and storage energies, coordination of tune meter kicks with TBT acquisition at 322 BPM's in each ring allows the measurement of local coupling at all BPM locations.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 798561
- Report Number(s):
- BNL-69223; R&D Project: AD003; KA0202011; TRN: US0204828
- Resource Relation:
- Conference: 2002 PARTICLE ACCELERATOR CONFERENCE, PARIS (FR), 06/02/2002--06/07/2002; Other Information: PBD: 2 Jun 2002
- Country of Publication:
- United States
- Language:
- English
Similar Records
The effect and correction of coupling generated by the RHIC triplet quadrupoles
PRINCIPLE OF GLOBAL DECOUPLING WITH COUPLING ANGLE MODULATION.