Analysis for Eccentric Multi Canister Overpack (MCO) Drops at the Canister Storage Building (CSB) (CSB-S-0073)

Technical Report ·
DOI:https://doi.org/10.2172/798142· OSTI ID:798142

Multi-Canister Overpacks (MCOs) containing spent nuclear fuel (SNF) will be routinely handled at the Canister Storage Building (CSB) during fuel movement operations in the SNF Project. This analysis was performed to investigate the potential for damage from an eccentric accidental drop onto the standard storage tube, overpack tube, service station, or sample/weld station. Appendix D was added to the FDNW document to include the peer Review Comment Record & transmittal record.

Research Organization:
FDNW (US)
Sponsoring Organization:
ENVIRONMENTAL MANAGEMENT (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
798142
Report Number(s):
SNF-5204, Rev.0; EDT-627587
Country of Publication:
United States
Language:
English