Transverse Wakefields from Tapered Collimators: Measurements and Analysis

Technical Report ·
DOI:https://doi.org/10.2172/787211· OSTI ID:787211
We report on a series of measurements of the transverse wakefield from tapered collimators. The collimators were designed to principally present a geometric impedance to the beam, and to minimize impedances from resistivity or surface features; in addition, the geometries of the collimators were selected to permit examination of the scaling behavior of the wakefield due to collimator taper angle and minimum gap size. We present the measured near-center wakefields of the collimators, as well as the effect of bunch-length variation. The measurements are compared to analytic models and MAFIA simulations.
Research Organization:
Stanford Linear Accelerator Center, Menlo Park, CA (US)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
787211
Report Number(s):
SLAC-PUB-8937
Country of Publication:
United States
Language:
English

Similar Records

Direct Measurement of the Transverse Wakefields of Tapered Collimators
Journal Article · Mon Jan 08 23:00:00 EST 2007 · Submitted to Physical Review Special Topics -- Accelerators and Beams · OSTI ID:897443

Direct Measurement of the Resistive Wakefield in Tapered Collimators
Technical Report · Mon Jul 26 00:00:00 EDT 2004 · OSTI ID:827348

Direct Measurement of Geometric and Resistive Wakefields in Tapered Collimators for the International Linear Collider
Conference · Fri Aug 18 00:00:00 EDT 2006 · OSTI ID:889668