Transformer ratio enhancement using a ramped bunch train in a collinear wakefield accelerator.
Conference
·
OSTI ID:783664
We present a practical method for achieving a transformer ratio (R) greater than 2 with any collinear wakefield accelerator--i.e. with either plasma or structure based wakefield accelerators. It is known that the transformer ratio cannot generally be greater than 2 for a symmetric drive bunch in a collinear wakefield accelerator. However, using a ramped bunch train (RBT) where a train of n electron drive bunches, with increasing (ramping) charge, one can achieve R = 2n after the bunch train. We believe this method is feasible from an engineering standpoint. We describe a proof of principle experiment using an disk-loaded waveguide, of frequency 13.65 GHz, driven by a RBT of 4 electron bunches. We expect to achieve R > 6 using 4 electron bunches. Details of the simulation and experimental design are presented.
- Research Organization:
- Argonne National Lab., IL (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 783664
- Report Number(s):
- ANL-HEP-CP-01-62
- Country of Publication:
- United States
- Language:
- English
Similar Records
High Transformer ratios in collinear wakefield accelerators.
Observation of enhanced transformer ratio in collinear Wakefield acceleration.
Observation of Enhanced Transformer Ratio in Collinear Wakefield Acceleration
Conference
·
Mon Dec 31 23:00:00 EST 2007
·
OSTI ID:972613
Observation of enhanced transformer ratio in collinear Wakefield acceleration.
Conference
·
Sat Dec 31 23:00:00 EST 2005
·
OSTI ID:973767
Observation of Enhanced Transformer Ratio in Collinear Wakefield Acceleration
Journal Article
·
Sun Nov 26 23:00:00 EST 2006
· AIP Conference Proceedings
·
OSTI ID:20898716