Design and performance of the main amplifier system for the National Ignition Facility
This paper describes the design and performance of flashlamp-pumped, Nd:glass. Brewster-angle slab amplifiers intended to be deployed in the National Ignition Facility (NIF). To verify performance, we tested a full-size, three-slab-long, NIF prototype amplifier, which we believe to be the largest flashlamp-pumped Nd:glass amplifier ever assembled. Like the NIF amplifier design, this prototype amplifier had eight 40-cm-square apertures combined in a four-aperture-high by two-aperture-wide matrix. Specially-shaped reflectors, anti-reflective coatings on the blastshields, and preionized flashlamps were used to increase storage efficiency. Cooling gas was flowed over the flashlamps to remove waste pump heat and to accelerate thermal wavefront recovery. The prototype gain results are consistent with model predictions and provide high confidence in the final engineering design of the NIF amplifiers. Although the dimensions, internal positions, and shapes of the components in the NIF amplifiers will be slightly different from the prototype, these differences are small and should produce only slight differences in amplifier performance
- Research Organization:
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA
- Sponsoring Organization:
- USDOE Office of Defense Programs (DP)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 7828
- Report Number(s):
- UCRL-JC-131963; 39DP02000; ON: DE00007828
- Country of Publication:
- United States
- Language:
- English
Similar Records
Accelerated thermal recovery for flash-lamp-pumped solid-state laser amplifiers final report for 97-ERD-133
Assembly and maintenance of full scale NIF amplifiers in the amplifier module prototype laboratory (AMPLAB)