Riser equipment decontamination engineering task plan
On October 15, 1998, two Characterization Project Operations (CPO) employees were found to have contaminated clothing. An operator had 300,000-dpm/100cm2 beta/gamma, no alpha, contamination on his coat sleeve and a Radiation Control Technician (RCT) had 10,000 dpm/100cm2 beta/gamma, no alpha, on his shirt sleeve. The CPO swing shift crew was working in TX tank farm, performing sampling activities at 241-TX-113. TX tank farm is a ''clean farm'' and does not require anti-contamination clothing for entry. The CPO personnel were dressed in normal work clothes. An operator and an RCT were performing a pre-job survey that involved removing bagging around the riser equipment. When the RCT saw that the contamination readings from smear samples of the riser equipment were greater than expected, the job was suspended. Crew members were then directed to areas of lower background radiation for personnel surveys. During personnel surveys, reportable contamination was found on the coat sleeve of the operator who had been involved in the pre-job survey and on the shirt sleeve of the RCT who had been involved in the pre-job survey. No other personnel were found to be contaminated. Because of this off normal event Characterization Engineering was given the following corrective action: Examine the process methodology used for core sampling operations to determine practicality and potential long-term advantages of reducing personnel contact with contaminated equipment. This Engineering Task Plan ensures that LMHC 1998a, Corrective Action No.7 is completely addressed by Characterization Engineering. The deliverable is an Engineering Study that evaluates decontamination of riser equipment components and considers additional engineered features to reduce potential exposure to workers operating the riser equipment. This engineering study shall also address any released design features that have failed to be implemented.
- Research Organization:
- HNF Hanford Site (US)
- Sponsoring Organization:
- US DOE Office of Environmental Management (US)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 782292
- Report Number(s):
- HNF--3700--REV0
- Country of Publication:
- United States
- Language:
- English
Similar Records
H-Coal pilot plant. Topical report: evaluation of a commercial laundry process for cleaning work clothing from a synthetic-fuels facility, E and H-12
Engineering task plan for purged light system
RCT: Module 2.07, Respiratory Protection, Course 8773
Technical Report
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:6255615
Engineering task plan for purged light system
Technical Report
·
Tue May 11 00:00:00 EDT 1999
·
OSTI ID:782287
RCT: Module 2.07, Respiratory Protection, Course 8773
Technical Report
·
Thu Aug 10 00:00:00 EDT 2017
·
OSTI ID:1375139