Title: HIGH TEMPERATURE HIGH PRESSURE THERMODYNAMIC MEASUREMENTS FOR COAL MODEL COMPOUNDS

Abstract

The flow VLE apparatus designed and built for a previous project was upgraded and recalibrated for data measurements for this project. The modifications include better and more accurate sampling technique, addition of a digital recorder to monitor temperature and pressure inside the VLE cell, and a new technique for remote sensing of the liquid level in the cell. VLE data measurements for three binary systems, tetralin-quinoline, benzene--ethylbenzene and ethylbenzene--quinoline, have been completed. The temperature ranges of data measurements were 325 C to 370 C for the first system, 180 C to 300 C for the second system, and 225 C to 380 C for the third system. The smoothed data were found to be fairly well behaved when subjected to thermodynamic consistency tests. SETARAM C-80 calorimeter was used for incremental enthalpy and heat capacity measurements for benzene--ethylbenzene binary liquid mixtures. Data were measured from 30 C to 285 C for liquid mixtures covering the entire composition range. An apparatus has been designed for simultaneous measurement of excess volume and incremental enthalpy of liquid mixtures at temperatures from 30 C to 300 C. The apparatus has been tested and is ready for data measurements. A flow apparatus for measurement of heatmore » of mixing of liquid mixtures at high temperatures has also been designed, and is currently being tested and calibrated.« less

Authors:
Publication Date:
Research Org.:
Federal Energy Technology Center, Morgantown, WV (US); Federal Energy Technology Center, Pittsburgh, PA (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
781758
Report Number(s):
DE-FG22-95PC95214-07
TRN: AH200123%%454
DOE Contract Number:  
FG22-95PC95214
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 1 May 2000
Country of Publication:
United States
Language:
English
Subject:
01 COAL, LIGNITE, AND PEAT; CALORIMETERS; COAL; ENTHALPY; MIXING HEAT; MIXTURES; MODIFICATIONS; REMOTE SENSING; SAMPLING; SPECIFIC HEAT; THERMODYNAMICS

Citation Formats

Vinayak N. Kabadi. HIGH TEMPERATURE HIGH PRESSURE THERMODYNAMIC MEASUREMENTS FOR COAL MODEL COMPOUNDS. United States: N. p., 2000. Web. doi:10.2172/781758.
Vinayak N. Kabadi. HIGH TEMPERATURE HIGH PRESSURE THERMODYNAMIC MEASUREMENTS FOR COAL MODEL COMPOUNDS. United States. doi:10.2172/781758.
Vinayak N. Kabadi. Mon . "HIGH TEMPERATURE HIGH PRESSURE THERMODYNAMIC MEASUREMENTS FOR COAL MODEL COMPOUNDS". United States. doi:10.2172/781758. https://www.osti.gov/servlets/purl/781758.
@article{osti_781758,
title = {HIGH TEMPERATURE HIGH PRESSURE THERMODYNAMIC MEASUREMENTS FOR COAL MODEL COMPOUNDS},
author = {Vinayak N. Kabadi},
abstractNote = {The flow VLE apparatus designed and built for a previous project was upgraded and recalibrated for data measurements for this project. The modifications include better and more accurate sampling technique, addition of a digital recorder to monitor temperature and pressure inside the VLE cell, and a new technique for remote sensing of the liquid level in the cell. VLE data measurements for three binary systems, tetralin-quinoline, benzene--ethylbenzene and ethylbenzene--quinoline, have been completed. The temperature ranges of data measurements were 325 C to 370 C for the first system, 180 C to 300 C for the second system, and 225 C to 380 C for the third system. The smoothed data were found to be fairly well behaved when subjected to thermodynamic consistency tests. SETARAM C-80 calorimeter was used for incremental enthalpy and heat capacity measurements for benzene--ethylbenzene binary liquid mixtures. Data were measured from 30 C to 285 C for liquid mixtures covering the entire composition range. An apparatus has been designed for simultaneous measurement of excess volume and incremental enthalpy of liquid mixtures at temperatures from 30 C to 300 C. The apparatus has been tested and is ready for data measurements. A flow apparatus for measurement of heat of mixing of liquid mixtures at high temperatures has also been designed, and is currently being tested and calibrated.},
doi = {10.2172/781758},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2000},
month = {5}
}