Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A Tutorial on Basic Principles of Microwave Reflectometry Applied to Fluctuation Measurements in Fusion Plasmas

Technical Report ·
DOI:https://doi.org/10.2172/775582· OSTI ID:775582
 [1]; ;
  1. Princeton Plasma Physics Laboratory
Microwave reflectometry is now routinely used for probing the structure of magnetohydrodynamic and turbulent fluctuations in fusion plasmas. Conditions specific to the core of tokamak plasmas, such as small amplitude of density irregularities and the uniformity of the background plasma, have enabled progress in the quantitative interpretation of reflectometer signals. In particular, the extent of applicability of the 1-D [one-dimensional] geometric optics description of the reflected field is investigated by direct comparison to 1-D full wave analysis. Significant advances in laboratory experiments are discussed which are paving the way towards a thorough understanding of this important measurement technique. Data is presented from the Tokamak Fusion Test Reactor [R. Hawryluk, Plasma Physics and Controlled Fusion 33 (1991) 1509] identifying the validity of the geometric optics description of the scattered field and demonstrating the feasibility of imaging turbulent fluctuations in fusion scale devices.
Research Organization:
Princeton Plasma Physics Lab., NJ (US)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC02-76CH03073
OSTI ID:
775582
Report Number(s):
PPPL-3545
Country of Publication:
United States
Language:
English

Similar Records

Fluctuation Measurements in Tokamaks with Microwave Imaging Reflectometry
Technical Report · Sun Dec 02 23:00:00 EST 2001 · OSTI ID:792990

Numerical Study of Microwave Reflectometry in Plasmas with 2D Turbulent Fluctuations
Technical Report · Sat Jan 31 23:00:00 EST 1998 · OSTI ID:4523

Application of microwave reflectometry to the measurement of fast magnetosonic waves in the Tokamak Fusion Test Reactor
Journal Article · Tue Dec 31 23:00:00 EST 1996 · Review of Scientific Instruments · OSTI ID:451776