Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Baseline and optional bench-scale testing of a chemical candle filter safeguard device

Technical Report ·
DOI:https://doi.org/10.2172/774907· OSTI ID:774907

This project was undertaken by the Energy and Environmental Research Center (EERC) to design, construct, and test the feasibility of a hot-gas filter safeguard device (SGD) to prevent the release of dust in the event of candle filter failure under both pressurized fluidized-bed combustion (PFBC) (oxidizing) and integrated gasification combined cycle (IGCC) (reducing) operating conditions. The SGD must use existing filter system seals, gaskets, fixtures, and assemblies as much as possible. It must also activate quickly when a candle filter has failed, preferably preventing dust concentrations downstream of the SGD from exceeding 1 ppmw. In addition, the SGD must be able to operate in an inactive mode with minimal pressure drop, and its operation cannot be affected by repeated backpulse cleaning events of up to 3 psia and 1/2 second in duration.

Research Organization:
Federal Energy Technology Center, Morgantown, WV (US); Federal Energy Technology Center, Pittsburgh, PA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC26-99FT40677
OSTI ID:
774907
Report Number(s):
DE--AC26-99FT40677-03
Country of Publication:
United States
Language:
English

Similar Records

A Simple Candle Filter Safeguard Device
Conference · Wed Sep 18 00:00:00 EDT 2002 · OSTI ID:835851

Novel Backup Filter Device for Candle Filters
Conference · Wed Sep 18 00:00:00 EDT 2002 · OSTI ID:835852

DEVELOPMENT OF AN ADHESIVE CANDLE FILTER SAFEGUARD DEVICE