Coupled THM analysis of the single-heater test at yucca mountain
Conference
·
OSTI ID:7722
- LLNL
This paper presents a summary of results from the Single-Heater Test (SHT) at Yucca Mountain, Nevada. In the SHT, a horizontal, 5-m-long, line-heat source was used to heat a rock pillar for nine months. Moisture movement was monitored during and after heating using electrical-resistance tomography (ERT) and neutron-logging techniques. Results indicate drying in regions of the rock where temperature reached 60°C and above. The drying zone is asymmetric and is not centered on the heater, but has lobes extending above and to the sides of the heater. Predicted temperatures agreed well with observations. A cold- trap effect was predicted, in the heater borehole, that efficiently transfers heat along the heater borehole to the excavation wall. A simple thermomechanical analysis of the SHT shows that shear zones predicted for vertical fractures coincide with regions of increased moisture content derived from ERT measurements.
- Research Organization:
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA
- Sponsoring Organization:
- USDOE Office of Civilian Radioactive Waste Management (RW)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 7722
- Report Number(s):
- UCRL-JC-132052; ON: DE00007722
- Country of Publication:
- United States
- Language:
- English
Similar Records
Electrical resistivity monitoring of the thermomechanical heater test in Yucca Mountain
Electrical resistivity monitoring of the thermomechanical heater test in Yucca Mountain
Mapping moisture distribution in Yucca Mountain using electrical resistance tomography
Conference
·
Sat Nov 30 23:00:00 EST 1996
·
OSTI ID:302176
Electrical resistivity monitoring of the thermomechanical heater test in Yucca Mountain
Conference
·
Wed Oct 01 00:00:00 EDT 1997
·
OSTI ID:526106
Mapping moisture distribution in Yucca Mountain using electrical resistance tomography
Conference
·
Mon Sep 01 00:00:00 EDT 1997
·
OSTI ID:651805