skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Rapid Measurement of Neutron Dose Rate for Transport Index

Abstract

A newly available neutron dose equivalent remmeter with improved sensitivity and energy response has been put into service at Rocky Flats Environmental Technology Site (RFETS). This instrument is being used to expedite measurement of the Transport Index and as an ALARA tool to identify locations where slightly elevated neutron dose equivalent rates exist. The meter is capable of measuring dose rates as low as 0.2 {mu}Sv per hour (20 {mu}rem per hour). Tests of the angular response and energy response of the instrument are reported. Calculations of the theoretical instrument response made using MCNP{trademark} are reported for materials typical of those being shipped.

Authors:
Publication Date:
Research Org.:
Safe Sites of Colorado, Golden, CO (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
769093
Report Number(s):
RFP-5272
TRN: US0100944
DOE Contract Number:  
AC04-90DP62349
Resource Type:
Conference
Resource Relation:
Conference: Waste Management 2000, Tucson, AZ (US), 02/27/2000--03/03/2000; Other Information: PBD: 27 Feb 2000
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ALARA; DOSE EQUIVALENTS; DOSE RATES; NEUTRONS; SENSITIVITY; TRANSPORT; WASTE MANAGEMENT; TRANSPORT INDEX; WENDI

Citation Formats

Morris, R.L. Rapid Measurement of Neutron Dose Rate for Transport Index. United States: N. p., 2000. Web.
Morris, R.L. Rapid Measurement of Neutron Dose Rate for Transport Index. United States.
Morris, R.L. Sun . "Rapid Measurement of Neutron Dose Rate for Transport Index". United States. https://www.osti.gov/servlets/purl/769093.
@article{osti_769093,
title = {Rapid Measurement of Neutron Dose Rate for Transport Index},
author = {Morris, R.L.},
abstractNote = {A newly available neutron dose equivalent remmeter with improved sensitivity and energy response has been put into service at Rocky Flats Environmental Technology Site (RFETS). This instrument is being used to expedite measurement of the Transport Index and as an ALARA tool to identify locations where slightly elevated neutron dose equivalent rates exist. The meter is capable of measuring dose rates as low as 0.2 {mu}Sv per hour (20 {mu}rem per hour). Tests of the angular response and energy response of the instrument are reported. Calculations of the theoretical instrument response made using MCNP{trademark} are reported for materials typical of those being shipped.},