High-power circulator test results at 350 and 700 MHz
Conference
·
OSTI ID:768261
The high-power RF systems for the Accelerator Production of Tritium (APT) program require high-power circulators at 350 MHz and 700 MHz to protect 1 MW Continuous Wave (CW) klystrons from reflected power. The 350 MHz circulator is based on the CERN, EXF, and APS designs and has performed very well. The 700 MHz circulator is a new design. Prototype 700 MHz circulators have been high-power tested at Los Alamos National Laboratory (LANL). The first of these circulators has satisfied performance requirements. The circulator requirements, results from the testing, and lessons learned from this development are presented and discussed.
- Research Organization:
- Los Alamos National Lab., NM (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 768261
- Report Number(s):
- LA-UR-00-3726
- Country of Publication:
- United States
- Language:
- English
Similar Records
Accelerator production of tritium 700 MHz and 350 MHz klystron test results
Design, operation, and test results of 350 MHz LEDA RF system
LEDA RF distribution system design and component test results
Technical Report
·
Wed Dec 30 23:00:00 EST 1998
·
OSTI ID:345047
Design, operation, and test results of 350 MHz LEDA RF system
Conference
·
Wed Dec 30 23:00:00 EST 1998
·
OSTI ID:345048
LEDA RF distribution system design and component test results
Conference
·
Wed Dec 30 23:00:00 EST 1998
·
OSTI ID:345043