Development and Evaluation of an Externally Air-Cooled Low-Flow torch and the Attenuation of Space Charge and Matrix Effects in Inductively Coupled Plasma Mass Spectrometry

Thesis/Dissertation ·
DOI:https://doi.org/10.2172/764685· OSTI ID:764685
 [1]
  1. Iowa State Univ., Ames, IA (United States)
An externally air-cooled low-flow torch has been constructed and successfully demonstrated for applications in inductively coupled plasma mass spectrometry (ICP-MS). The torch is cooled by pressurized air flowing at ~70 L/min through a quartz air jacket onto the exterior of the outer tube. The outer gas flow rate and operating RF forward power are reduced considerably. Although plasmas can be sustained at the operating power as low as 400 W with a 2 L/min of outer gas flow, somewhat higher power and outer gas flows are advisable. A stable and analytical useful plasma can be obtained at 850 W with an outer gas flow rate of ~4 L/min. Under these conditions, the air-cooled plasma produces comparable sensitivities, doubly charged ion ratios, matrix effects and other analytical merits as those produced by a conventional torch while using significantly less argon and power requirements. Metal oxide ion ratios are slightly higher with the air-cooled plasma but can be mitigated by reducing the aerosol gas flow rate slightly with only minor sacrifice in analyte sensitivity. A methodology to alleviate the space charge and matrix effects in ICP-MS has been developed. A supplemental electron source adapted from a conventional electron impact ionizer is added to the base of the skimmer. Electrons supplied from this source downstream of the skimmer with suitable amount and energy can neutralize the positive ions in the beam extracted from the plasma and diminish the space charge repulsion between them. As a result, the overall ion transmission efficiency and consequent analyte ion sensitivities are significantly improved while other important analytical aspects, such as metal oxide ion ratio, doubly charged ion ratio and background ions remain relatively unchanged with the operation of this electron source. This technique not only improves the ion transmission efficiency but also minimizes the matrix effects drastically. The matrix-induced suppression of signal for even the most troublesome combination of light analyte and heavy matrix elements can be attenuated from 90-99% to only 2-10% for 2 mM matrix solutions with an ultrasonic nebulizer. The supplemental electron current can be adjusted to ''titrate'' out the matrix effects as desired.
Research Organization:
Ames Lab., Ames, IA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-82
OSTI ID:
764685
Report Number(s):
IS--T 1893
Country of Publication:
United States
Language:
English

Similar Records

Matrix effects in inductively coupled plasma mass spectrometry
Thesis/Dissertation · Fri Jul 07 00:00:00 EDT 1995 · OSTI ID:108087

Laminar-flow torch for helium inductively coupled plasma spectrometry
Journal Article · Mon Nov 14 23:00:00 EST 1988 · Anal. Chem.; (United States) · OSTI ID:6357611

Continuum flow sampling mass spectrometer for elemental analysis with an inductively coupled plasma ion source
Technical Report · Sat Jun 01 00:00:00 EDT 1985 · OSTI ID:5612693