Title: Verification of MCNP and DANT/sys With the Analytic Benchmark Test Set

Abstract

The recently published analytic benchmark test set has been used to verify the multigroup option of MCNP and also the deterministic DANT/sys series of codes for criticality calculations. All seventy-five problems of the test set give values for K{sub eff} accurate to at least five significant digits. Flux ratios and flux shapes are also available for many of the problems. All seventy-five problems have been run by both the MCNP and DANT/sys codes and comparisons to K{sub eff} and flux shapes have been made. Results from this verification exercise are given below.

Authors:
; ; ;
Publication Date:
Research Org.:
Los Alamos National Lab., NM (US)
Sponsoring Org.:
USDOE Office of Environmental Management (EM) (US)
OSTI Identifier:
762718
Report Number(s):
LA-UR-99-2566
TRN: US0100501
DOE Contract Number:  
W-7405-ENG-36
Resource Type:
Conference
Resource Relation:
Conference: Sixth International Conference on Nuclear Criticality Safety, Versailles (FR), 09/20/1999--09/24/1999; Other Information: PBD: 20 Sep 1999
Country of Publication:
United States
Language:
English
Subject:
73 NUCLEAR PHYSICS AND RADIATION PHYSICS; BENCHMARKS; CRITICALITY; SAFETY; VERIFICATION

Citation Formats

Parsons, D.K., Sood, A., Forster, R.A., and Little, R.C. Verification of MCNP and DANT/sys With the Analytic Benchmark Test Set. United States: N. p., 1999. Web.
Parsons, D.K., Sood, A., Forster, R.A., & Little, R.C. Verification of MCNP and DANT/sys With the Analytic Benchmark Test Set. United States.
Parsons, D.K., Sood, A., Forster, R.A., and Little, R.C. Mon . "Verification of MCNP and DANT/sys With the Analytic Benchmark Test Set". United States. https://www.osti.gov/servlets/purl/762718.
@article{osti_762718,
title = {Verification of MCNP and DANT/sys With the Analytic Benchmark Test Set},
author = {Parsons, D.K. and Sood, A. and Forster, R.A. and Little, R.C.},
abstractNote = {The recently published analytic benchmark test set has been used to verify the multigroup option of MCNP and also the deterministic DANT/sys series of codes for criticality calculations. All seventy-five problems of the test set give values for K{sub eff} accurate to at least five significant digits. Flux ratios and flux shapes are also available for many of the problems. All seventy-five problems have been run by both the MCNP and DANT/sys codes and comparisons to K{sub eff} and flux shapes have been made. Results from this verification exercise are given below.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1999},
month = {9}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: