CASMO Doppler coefficients versus MCNP-3A Monte Carlo calculations
Journal Article
·
· Transactions of the American Nuclear Society
OSTI ID:76090
CASMO has previously been benchmarked against the Hellstrand measured resonance integrals and Doppler coefficients. The benchmarks shows that CASMO-calculated Doppler coefficients are within the measured uncertainty of 8% for a wide range of resonance shielding typical for boiling water reactor (BWR) and pressurized water reactor (PWR) lattices. This paper presents results from benchmark calculations for PWR pin cells. CASMO-3 and CASMO-4 results are compared with published reference solutions from MCNP-3A continuous-energy Monte Carlo calculations using ENDF/B-V cross-section data.
- OSTI ID:
- 76090
- Report Number(s):
- CONF-940602--
- Journal Information:
- Transactions of the American Nuclear Society, Journal Name: Transactions of the American Nuclear Society Vol. 70; ISSN 0003-018X; ISSN TANSAO
- Country of Publication:
- United States
- Language:
- English
Similar Records
Benchmark calculations for the Doppler coefficient of reactivity
Doppler evaluations based on ENDF/B-V (Evaluated Nuclear Data File)
ENDF/B-V cell comparisons and MCNP-3A