Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Radiation monitoring during criticality at a gaseous diffusion plant

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:75978
The Paducah gaseous diffusion plant (PGDP) has two systems of radiation detection units that monitor radiation associated with a nuclear criticality accident (NCA). The primary system, the criticality accident alarm system (CAAS), is composed of several detection units that alarm when gamma-radiation levels exceed 10 mR/h. The CAAS provides the means to initiate emergency-evacuation procedures in the event of an NCA. This system is augmented with a second system of radiation detectors, which is referred to as the argon gamma graph (AGG) system. The AGG system is utilized specifically for the remote monitoring of radiation during an NCA and is a primary tool used by emergency response personnel. The remote radiation readings supplied by the AGG system provide the means to quickly locate and characterize an NCA. The centralized remote monitoring of radiation during an NCA permits important data to be collected efficiently without subjecting personnel to unknown and unquantified radiation fields. Calculations of the expected radiation readings on the AGG system were performed for a postulated NCA at four different locations at PGDP.
OSTI ID:
75978
Report Number(s):
CONF-940602--
Journal Information:
Transactions of the American Nuclear Society, Journal Name: Transactions of the American Nuclear Society Vol. 70; ISSN 0003-018X; ISSN TANSAO
Country of Publication:
United States
Language:
English