Evaluation of Iron Aluminide Weld Overlays for Erosion-Corrosion Resistant Boiler Tube Coatings in Low NOx Boilers

Technical Report ·
DOI:https://doi.org/10.2172/757303· OSTI ID:757303
Iron aluminide weld overlays containing ternary additions and thermal spray coatings are being investigated for corrosion protection of boiler tubes in Low NO{sub x} burners. The primary objective of the research is to identify overlay and thermal spray compositions that provide corrosion protection of waterwall boiler tubes.
Research Organization:
Oak Ridge National Lab., TN (US)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
757303
Report Number(s):
ORNL/Sub/95-SU604/03
Country of Publication:
United States
Language: