Thermal Analysis of the 9975 Package as a Plutonium Storage Container
Conference
·
OSTI ID:7553
Thermal analyses of three plutonium storage configurations (two plutonium metal and one plutonium oxide) consisting of the 3013 container within the 9975 package have been performed. All analyses are steady-state with 19 watts of Pu as contents. The analyzed conditions include allowance for storing the 9975 in a lattice configuration with stacking in a maximum ambient temperature 130 degrees F (54.4 degrees C) (assuming total loss of ventilation) and an ambient of 200 degrees F (93.3 degrees C) during accident (fire) conditions.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 7553
- Report Number(s):
- WSRC-MS-99-00217; ON: DE00007553
- Resource Relation:
- Conference: American Society of Mechanical Engineers Pressure Vessel and Piping Conference, Boston, MA (USA), 1-5 Aug 1999
- Country of Publication:
- United States
- Language:
- English
Similar Records
Thermal Analysis of the 9975 Package with the 3013 Configuration During Normal Conditions of Transport
DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-00600
Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC (2022 Status Report)
Technical Report
·
Mon Feb 22 00:00:00 EST 1999
·
OSTI ID:7553
DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-00600
Technical Report
·
Mon Oct 29 00:00:00 EDT 2007
·
OSTI ID:7553
Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC (2022 Status Report)
Technical Report
·
Thu Sep 01 00:00:00 EDT 2022
·
OSTI ID:7553