skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Thermal Analysis of the 9975 Package as a Plutonium Storage Container

Conference ·
OSTI ID:7553

Thermal analyses of three plutonium storage configurations (two plutonium metal and one plutonium oxide) consisting of the 3013 container within the 9975 package have been performed. All analyses are steady-state with 19 watts of Pu as contents. The analyzed conditions include allowance for storing the 9975 in a lattice configuration with stacking in a maximum ambient temperature 130 degrees F (54.4 degrees C) (assuming total loss of ventilation) and an ambient of 200 degrees F (93.3 degrees C) during accident (fire) conditions.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC09-96SR18500
OSTI ID:
7553
Report Number(s):
WSRC-MS-99-00217; ON: DE00007553
Resource Relation:
Conference: American Society of Mechanical Engineers Pressure Vessel and Piping Conference, Boston, MA (USA), 1-5 Aug 1999
Country of Publication:
United States
Language: