Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Abuse tests on sealed lead-acid batteries

Technical Report ·
DOI:https://doi.org/10.2172/753376· OSTI ID:753376

Abuse tests were conducted on the lead-acid batteries used to power electrical testers used at the Department of Energy's Pantex Plant. Batteries were subjected to short circuits, crushes, penetrations, and drops. None of the observed responses would be a threat to nuclear explosive safety in a bay or cell at Pantex. Temperatures, currents, and damage were measured and recorded during the tests.

Research Organization:
Sandia National Labs., Albuquerque, NM (US); Sandia National Labs., Livermore, CA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
753376
Report Number(s):
SAND2000-0709
Country of Publication:
United States
Language:
English

Similar Records

Battery Abuse Testing
Technical Report · Mon Jan 20 23:00:00 EST 2020 · OSTI ID:1592935

Testing of sealed lead-acid batteries
Technical Report · Tue Jan 31 23:00:00 EST 1984 · OSTI ID:5312692

Testing of sealed lead-acid batteries. Revision