Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Deflagration transient study of the CIF incinerator

Conference ·
OSTI ID:752204
The Consolidated Incineration Facility (CIF) treats solid and liquid RCRA hazardous and mixed wastes generated at the Savannah River Site (SRS). The transient responses of the CIF system to a deflagration, caused by an accidental charge of a modest quantity of solvent (e.g. toluene) into the rotary kiln, were a major safety concern. Using a dynamic computer model, a study was conducted to analyze the transient system responses to the rapid temperature and pressure surge in the kiln. The objective of the study was to determined the maximum pressure, temperature, and gas flow rate in each CIF component (rotary kiln, secondary combustion chamber, quencher, scrubber/cyclone, mist eliminator, reheaters, HEPAs, and ID fans). The resulting data provided a basis for the subsequent structural analysis. This paper will describe the CIF deflagration study in some detail, and present the results of the simulation scenarios.
Research Organization:
Savannah River Site (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC09-96SR18500
OSTI ID:
752204
Report Number(s):
WSRC-MS-99-00944
Country of Publication:
United States
Language:
English