Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Relocation impacts of an H-Separations coil and tube failure

Technical Report ·
DOI:https://doi.org/10.2172/752132· OSTI ID:752132

The relocation impacts of an accidental release, scenario 1-RD-2.35, are evaluated for H-Separations. The extent of the area potentially contaminated to a level that would result in doses exceeding the relocation protective action guide (PAG) is calculated. The maximum calculated distance downwind from the accident at which the relocation PAG is exceeded is also determined. The consequences of the release are evaluated using the HOTSPOT model and an EXCEL spreadsheet.

Research Organization:
Savannah River Site (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC09-96SR18500
OSTI ID:
752132
Report Number(s):
WSRC-TR-99-00104-Rev.1
Country of Publication:
United States
Language:
English

Similar Records

Relocation Impacts of an H-Separations Coil and Tube Failure
Technical Report · Wed Aug 04 00:00:00 EDT 1999 · OSTI ID:9557

Relocation impacts of a major release from SRTC
Technical Report · Tue Jun 01 00:00:00 EDT 1999 · OSTI ID:9849

Ingestion Pathway Consequences of an H-Separations Coil and Tube Failure
Technical Report · Wed Aug 04 00:00:00 EDT 1999 · OSTI ID:9556