Dissipated power measurements in the A0 SRF cavity system
Conference
·
OSTI ID:751362
- Fermilab
Fermilab operates a single TESLA 9-cell superconducting RF cavity in support of a photoelectron R and D beam line. Power going into the 1.8K cryogenic system via static heat leak and RF dissipation is measured from the rate of rise of the pressure in the helium bath. This paper describes the techniques used to determine the cryostat heat load and the RF performance of the cavity. A photo-injector has been constructed at Fermilab to produce a low-energy (14--18 MeV) electron beam with high charge per bunch (8 nC), short bunch length (1 mm RMS), and small transverse emittance (<20 mm mrad). The facility was used to commission a photo-cathode RF gun for the TESLA Test Facility (TTF) Linac at DESY. At present, the Fermilab machine is being used for R and D in bunch length compression and fast beam diagnostics; experiments in plasma wake field acceleration and channeling acceleration are in preparation.
- Research Organization:
- Fermi National Accelerator Lab., Batavia, IL (US)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 751362
- Report Number(s):
- FERMILAB--Conf-00/010-E
- Country of Publication:
- United States
- Language:
- English
Similar Records
Beam test of a superconducting cavity for the Fermilab high-brightness electron photo-injector
First results of the Fermilab high-brightness RF photoinjector
Studies of photo-emission and field emission in an RF photo-injector with a high quantum efficiency photo-cathode
Conference
·
Tue May 04 00:00:00 EDT 1999
·
OSTI ID:6572
First results of the Fermilab high-brightness RF photoinjector
Conference
·
Mon Oct 25 00:00:00 EDT 1999
·
OSTI ID:14017
Studies of photo-emission and field emission in an RF photo-injector with a high quantum efficiency photo-cathode
Conference
·
Fri Aug 10 00:00:00 EDT 2001
·
OSTI ID:784270