Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Analysis of the interphase of a polyamide bonded to chromic acid anodized Ti-6AL-4V

Conference ·
OSTI ID:750236

Structural adhesive joints, when tested as made, typically fail cohesively through the centerline of the adhesive. However, in any study of adhesive joint durability, failure near the adhesive/substrate interface becomes an important consideration. In the current study, an interfacially debonding adhesive test, the notched coating adhesion (NCA) test, was applied to LaRC(trademark) PETI-5 adhesive bonded to chronic acid anodized (CAA) Ti-6Al-4V. Post-failure analysis of the interphase region included X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), field emission scanning electron microscopy (FE-SEM), and atomic force microscopy (AFM). Mechanical interlocking between an adhesive and a substrate occurs when the liquid adhesive flows into interstices of the substrate, solidifies, and becomes locked in place. Mechanical interlocking is believed to significantly contribute to the adhesion of substrates that exhibit microroughness, such as metal surfaces treated with chromic acid anodization or sodium hydroxide anodization. Filbey and Wightman found that an epoxy penetrated the pores of CAA Ti-6Al-4V, one of the limited number of pore penetration studies that have been reported. In the current study, the penetration of PETI-5 into the pores of CAA Ti-6Al-4V is investigated through analysis of adhesive/substrate failure surfaces.

Research Organization:
Sandia National Labs., Albuquerque, NM (US); Sandia National Labs., Livermore, CA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
750236
Report Number(s):
SAND2000-0065C
Country of Publication:
United States
Language:
English

Similar Records

Failure Surface Analysis of Polyimide/Titanium Notched Coating Adhesion Specimens
Journal Article · Sun Dec 17 23:00:00 EST 2000 · Journal of Adhesion · OSTI ID:772051

Evaluation of Ti-6Al-4V surface treatments for use with a polyphenylquinoxaline adhesive
Technical Report · Wed Oct 01 00:00:00 EDT 1986 · OSTI ID:6973561

Durability of Ti-6Al-4V/LaRC-PETI-5 adhesive bonded system for HSCT applications