Electrochemical etching amplification of low-let recoil particle tracks in polymers for fast neutron dosimetry
Technical Report
·
OSTI ID:7364336
An electrochemical etching method for the amplification of fast-neutron-induced recoil particle tracks in polymers was investigated. The technique gave superior results over those obtained by conventional etching methods especially when polycarbonate foils were used for recoil particle track amplification. Electrochemical etching systems capable of multi-foil processing were designed and constructed to demonstrate the feasibility of the techniques for large-scale neutron dosimetry. Electrochemical etching parameters were studied including the nature or type of the polymer foil used, foil thickness and its effect on etching time, the applied voltage and its frequency, the chemical composition, concentration, and temperature of the etchant, distance and angle between the electrodes, and the type of particles such as recoil particles including protons. Recoil particle track density, mean track diameter, and optical density as functions of the mentioned parameters were determined. Each parameter was found to have a distinct effect on the etching results in terms of the measured responses. Several new characteristics of this fast neutron dosimetry method were studied especially for personnel dosimetry using various radiation sources such as nuclear reactors, medical cyclotrons, and isotopic neutron sources. The dose range, neutron energy dependence, directional response, fading characteristics, neutron threshold energy, etc. were investigated.
- Research Organization:
- Georgia Inst. of Tech., Atlanta (USA). School of Nuclear Engineering
- OSTI ID:
- 7364336
- Report Number(s):
- ORO-4814-5
- Country of Publication:
- United States
- Language:
- English
Similar Records
Neutron dosimetry using electrochemical etching
Some studies on the development and applications of recoil particle track amplification by electrochemical etching for fast neutron dosimetry. Progress report. [For measuring neutron contamination in x-ray beams of medical accelerators]
New polycarbonate fast neutron personnel dosimeter
Conference
·
Fri Dec 31 23:00:00 EST 1976
·
OSTI ID:5264687
Some studies on the development and applications of recoil particle track amplification by electrochemical etching for fast neutron dosimetry. Progress report. [For measuring neutron contamination in x-ray beams of medical accelerators]
Technical Report
·
Sat May 01 00:00:00 EDT 1976
·
OSTI ID:7176056
New polycarbonate fast neutron personnel dosimeter
Journal Article
·
Thu Jun 01 00:00:00 EDT 1978
· Am. Ind. Hyg. Assoc. J.; (United States)
·
OSTI ID:5468573
Related Subjects
440102* -- Radiation Instrumentation-- Radiation Dosemeters
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
BARYONS
DIELECTRIC TRACK DETECTORS
DOSIMETRY
ELEMENTARY PARTICLES
ETCHING
FAST NEUTRONS
FERMIONS
HADRONS
MEASURING INSTRUMENTS
NEUTRON DOSIMETRY
NEUTRONS
NUCLEONS
PARTICLE TRACKS
PERFORMANCE
POLYMERS
RADIATION DETECTORS
RECOILS
SURFACE FINISHING
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
BARYONS
DIELECTRIC TRACK DETECTORS
DOSIMETRY
ELEMENTARY PARTICLES
ETCHING
FAST NEUTRONS
FERMIONS
HADRONS
MEASURING INSTRUMENTS
NEUTRON DOSIMETRY
NEUTRONS
NUCLEONS
PARTICLE TRACKS
PERFORMANCE
POLYMERS
RADIATION DETECTORS
RECOILS
SURFACE FINISHING