Flyer plate adhesion tests for copper and nickel plated A286 stainless steel

Journal Article · · Rev. Sci. Instrum.; (United States)
DOI:https://doi.org/10.1063/1.1134149· OSTI ID:7359305
Flyer plate shock wave tests were used to evaluate the influence of using an intermediate copper electrodeposited coating on A286 stainless steel prior to plating to final thickness with nickel. Neither varying the copper plating solution (cyanide or pyrophosphate) nor the deposit thickness from 0.008 to 0.084 mm affected the adhesion.
Research Organization:
Sandia Labs., Livermore, CA
OSTI ID:
7359305
Journal Information:
Rev. Sci. Instrum.; (United States), Journal Name: Rev. Sci. Instrum.; (United States) Vol. 46:12; ISSN RSINA