Exposure study for dry-film photoresists. [Production of printed wiring boards]
Ultraviolet-light exposure settings have been established for a Gyrex Conex Model 971 exposure unit to provide optimum exposure for DuPont Riston negative-acting dry-film photoresist Types 6S, 16, and 30, as well as for the new Types 110S and 116S. The amount of light undercut has been determined for Types 110S and 116S when used with both negative and positive phototools for the production of printed wiring boards.
- Research Organization:
- Bendix Corp., Kansas City, MO (United States)
- DOE Contract Number:
- E(29-1)-613
- OSTI ID:
- 7349317
- Report Number(s):
- BDX-613-1469
- Country of Publication:
- United States
- Language:
- English
Similar Records
Characterization of DuPont 9015, aqueous processable dry film photoresist for printed wiring boards. Topical report
Evaluation of alkaline etchants for printed wiring boards
Sandia/Bendix standard process capability study of printed wiring boards
Technical Report
·
Sat Apr 01 00:00:00 EST 1995
·
OSTI ID:7349317
Evaluation of alkaline etchants for printed wiring boards
Technical Report
·
Wed Sep 01 00:00:00 EDT 1976
·
OSTI ID:7349317
Sandia/Bendix standard process capability study of printed wiring boards
Technical Report
·
Sun Aug 01 00:00:00 EDT 1976
·
OSTI ID:7349317