SLIFER (Short Location Indication by Frequency of Electrical Resonance) systems measure stress wave velocity in solid or liquid materials. They monitor underground nuclear detonations at the Nevada Test Site (NTS). A shorted length of coaxial cable is a component in an oscillator's tank circuit. This sensor cable is inductive when less than one-fourth wavelength long at the oscillator's resonant frequency. The stress wave from a detonation crushes and shorts this sensor cable. As the short proceeds, inductance decreases and oscillator frequency increases. Later we convert frequency vs time to shock-front position vs time. Some doubt existed about the reliable operation of the oscillators in cold weather. Therefore these tests were conducted to check their reliability under several conditions: (1) at temperatures from -40/sup 0/ to 60/sup 0/C; (2) with three sensor cable lengths; (3) with sensor cables shorted or open at the far end; and (4) at two input power voltages. Results are presented.