Martins Creek SES 800 MW-Units 3 and 4: design and operating experience with axial flow FD and ID fans
Journal Article
·
· Combustion; (United States)
OSTI ID:7341706
The Martins Creek SES units 3 and 4 are 820 MW crude oil- or residual oil-fired power units. The forced draft and induced draft fans used in the plants are variable pitch axial flow units. The design, operation, maintenance, and field testing of these fans are discussed. (LCL)