Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Test of 6-in. -thick pressure vessels. Series 3: intermediate test vessel V-7. [PWR and BWR]

Technical Report ·
DOI:https://doi.org/10.2172/7331255· OSTI ID:7331255

The test of intermediate test vessel V-7 was a crack-initiation fracture test of a 152-mm-thick (6-in.), 990-mm-OD (39-in.) vessel of ASTM A533, grade B, class 1 steel plate with a sharp outside surface flaw 457 mm (18 in.) long and about 135 mm (5.3 in.) deep. The vessel was heated to 91/sup 0/C (196/sup 0/F) and pressurized hydraulically until leakage through the flaw terminated the test at a peak pressure of 147 MPa (21,350 psi). Fracture toughness data obtained by testing precracked Charpy-V and compact-tension specimens machined from a prolongation of the cylindrical test shell were used in pretest analyses of the flawed vessel. The vessel, as expected, did not burst. Upon depressurization, the ruptured ligament closed so as to maintain static pressure without leakage at about 129 MPa (18,700 psi).

Research Organization:
Oak Ridge National Lab., Tenn. (USA)
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
7331255
Report Number(s):
ORNL/NUREG-1
Country of Publication:
United States
Language:
English