Title: SNAP 10A FS-3 reactor performance

Abstract

SNAP 10FS-3 was the first flight-qualified SNAP reactor system to be operated in a simulated space environment. Prestart-up qualification testing, automatic start-up, endurance period performance, extended operation test and reactor shutdown are described as they affected, or were affected by, overall reactor performance. Performance of the reactor control system and the diagnostic instrumentation is critically evaluted.

Authors:
;
Publication Date:
Research Org.:
Atomics International Div., Canoga Park, CA (USA)
OSTI Identifier:
7315563
Report Number(s):
NAA-SR-11397
DOE Contract Number:  
E(11-1)-GEN-8
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S10FS-3 REACTOR; PERFORMANCE TESTING; PERFORMANCE; REACTOR CONTROL SYSTEMS; REACTOR INSTRUMENTATION; REACTOR OPERATION; CONTROL SYSTEMS; ENRICHED URANIUM REACTORS; LIQUID METAL COOLED REACTORS; MOBILE REACTORS; NAK COOLED REACTORS; OPERATION; POTASSIUM COOLED REACTORS; POWER REACTORS; PROCESS HEAT REACTORS; REACTORS; SNAP 10 REACTOR; SNAP REACTORS; SODIUM COOLED REACTORS; SPACE POWER REACTORS; TESTING; NESDPS Office of Nuclear Energy Space and Defense Power Systems; 210600* - Power Reactors, Auxiliary, Mobile Package, & Transportable

Citation Formats

Hawley, J P, and Johnson, R A. SNAP 10A FS-3 reactor performance. United States: N. p., 1966. Web. doi:10.2172/7315563.
Hawley, J P, & Johnson, R A. SNAP 10A FS-3 reactor performance. United States. doi:10.2172/7315563.
Hawley, J P, and Johnson, R A. Mon . "SNAP 10A FS-3 reactor performance". United States. doi:10.2172/7315563. https://www.osti.gov/servlets/purl/7315563.
@article{osti_7315563,
title = {SNAP 10A FS-3 reactor performance},
author = {Hawley, J P and Johnson, R A},
abstractNote = {SNAP 10FS-3 was the first flight-qualified SNAP reactor system to be operated in a simulated space environment. Prestart-up qualification testing, automatic start-up, endurance period performance, extended operation test and reactor shutdown are described as they affected, or were affected by, overall reactor performance. Performance of the reactor control system and the diagnostic instrumentation is critically evaluted.},
doi = {10.2172/7315563},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1966},
month = {8}
}