Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Impurities in the plasma with a high electron density in the TM-3 tokamak

Journal Article · · Sov. J. Plasma Phys. (Engl. Transl.); (United States)
OSTI ID:7306092
The method of x-ray spectroscopy is used to measure the effective charge of a plasma with n/sub e/(0) =8 x 10/sup 13/ and T/sub e/(0) =1 keV. The energies of the detected x rays lie in the range 2.5--7 keV. The value of Z/sub eff/ turns out to be 2 and is distributed uniformly over the plasma cross section. Recombination is incorporated in the calculation of Z/sub eff/. It is assumed that t the plasma is contaminated by an impurity of only a single species, oxygen or iron. The corresonding ion densities at the center of the plasma turn out to be n/sub i/=6 x 10/sup 11/ and 10/sup 11/ cm/sup -3/.
Research Organization:
I. V. Kurchatov Institute of Atomic Energy, Moscow
OSTI ID:
7306092
Journal Information:
Sov. J. Plasma Phys. (Engl. Transl.); (United States), Journal Name: Sov. J. Plasma Phys. (Engl. Transl.); (United States) Vol. 2:6; ISSN SJPPD
Country of Publication:
United States
Language:
English

Similar Records

Murakami density limit in tokamaks and reversed-field pinches
Journal Article · Fri May 31 20:00:00 EDT 1985 · Phys. Fluids; (United States) · OSTI ID:5816772

Effective charge state in a tokamak with a graphite wall and a graphite limiter (TM-G)
Journal Article · Fri Oct 31 23:00:00 EST 1986 · Sov. J. Plasma Phys. (Engl. Transl.); (United States) · OSTI ID:6778690

Murakami density limit in tokamaks and reversed-field pinches
Technical Report · Wed Feb 29 19:00:00 EST 1984 · OSTI ID:5194209