Use of thin Mylar film in optical spark chambers

Journal Article · · Instrum. Exp. Tech. (USSR) (Engl. Transl.); (United States)
OSTI ID:7305028

The possibility is demonstrated of using thin Mylar film as a window material through which sparks are photographed. Film 70-..mu.. thick was investigated, which was used in the spark chambers of the neutrino detector at the Institute of Theoretical and Experimental Physics. The mean-square angular displacement of the object image due to local inhomogeneities of the film amounts to (6.3 +- 0.3) 10/sup -5/ rad for a linear dimension of approximately 2 mm of the sector on the Mylar film through which the light passes.

Research Organization:
Inst. of Theoretical and Experimental Physics, Moscow
OSTI ID:
7305028
Journal Information:
Instrum. Exp. Tech. (USSR) (Engl. Transl.); (United States), Journal Name: Instrum. Exp. Tech. (USSR) (Engl. Transl.); (United States) Vol. 19:4; ISSN INETA