Physical aspects of electron-beam arc therapy
Conference
·
· Radiology; (United States)
OSTI ID:7284809
The effect of different parameters on dose distribution in electron-beam arc therapy was studied in order to develop a technique for routine clinical use. A special diaphragm was designed to facilitate telecentric rotation. Dosimetry was performed with an ion chamber, film, and LiF powder in cylindrical polystyrene phantoms and an Alderson Rando phantom. Dose distributions were evaluated with regard to dose homogeneity, and a method of sharpening the dose fall-off near the ends of the arc was proposed. Criteria for selection of isocenter depth and field size were developed. Methods of dose calculation, calibration, and treatment planning are discussed.
- Research Organization:
- Univ. of Minnesota Hospitals, Minneapolis
- OSTI ID:
- 7284809
- Conference Information:
- Journal Name: Radiology; (United States) Journal Volume: 124:2
- Country of Publication:
- United States
- Language:
- English
Similar Records
Dynamic conformal arc therapy: Transmitted signal in vivo dosimetry
Physical aspects of the angle-beta concept in electron arc therapy
SU-E-T-138: Dosimetric Verification For Volumetric Modulated Arc Therapy Cranio-Spinal Irradiation Technique
Journal Article
·
Thu May 15 00:00:00 EDT 2008
· Medical Physics
·
OSTI ID:21120687
Physical aspects of the angle-beta concept in electron arc therapy
Journal Article
·
Sat Jun 01 00:00:00 EDT 1991
· International Journal of Radiation Oncology, Biology and Physics; (United States)
·
OSTI ID:5507563
SU-E-T-138: Dosimetric Verification For Volumetric Modulated Arc Therapy Cranio-Spinal Irradiation Technique
Journal Article
·
Sun Jun 01 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22339892
Related Subjects
61 RADIATION PROTECTION AND DOSIMETRY
655003* -- Medical Physics-- Dosimetry
BEAMS
CALIBRATION
DOSIMETRY
ELECTRON BEAMS
ELECTRON DOSIMETRY
LEPTON BEAMS
MEDICINE
MOCKUP
NUCLEAR MEDICINE
ORGANIC COMPOUNDS
ORGANIC POLYMERS
PARTICLE BEAMS
PETROCHEMICALS
PETROLEUM PRODUCTS
PHANTOMS
PLASTICS
POLYMERS
POLYOLEFINS
POLYSTYRENE
POLYVINYLS
RADIATION DOSE DISTRIBUTIONS
RADIOLOGY
RADIOTHERAPY
SPATIAL DOSE DISTRIBUTIONS
STRUCTURAL MODELS
THERAPY
655003* -- Medical Physics-- Dosimetry
BEAMS
CALIBRATION
DOSIMETRY
ELECTRON BEAMS
ELECTRON DOSIMETRY
LEPTON BEAMS
MEDICINE
MOCKUP
NUCLEAR MEDICINE
ORGANIC COMPOUNDS
ORGANIC POLYMERS
PARTICLE BEAMS
PETROCHEMICALS
PETROLEUM PRODUCTS
PHANTOMS
PLASTICS
POLYMERS
POLYOLEFINS
POLYSTYRENE
POLYVINYLS
RADIATION DOSE DISTRIBUTIONS
RADIOLOGY
RADIOTHERAPY
SPATIAL DOSE DISTRIBUTIONS
STRUCTURAL MODELS
THERAPY