Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

MAAP PWR application guidelines for Westinghouse and Combustion Engineering plants

Technical Report ·
OSTI ID:7281320
 [1];  [2]
  1. Gabor, Kenton and Associates, Inc., Westmont, IL (United States)
  2. Levy (S.), Inc., Campbell, CA (United States)
The Modular Accident Analysis Program (MAAP) simulates LWR system response to a severe core accident. Overall, calculations performed with the PWR version of MAAP have compared well with a wide variety of other data. These results have proven MAAP an acceptable tool to support individual plant examinations and accident management. This report provides application guidelines for using the PWR version of the MAAP code in Westinghouse and Combustion Engineering plants.
Research Organization:
Electric Power Research Inst., Palo Alto, CA (United States); Gabor, Kenton and Associates, Inc., Westmont, IL (United States); Levy (S.), Inc., Campbell, CA (United States)
Sponsoring Organization:
EPRI; Electric Power Research Inst., Palo Alto, CA (United States)
OSTI ID:
7281320
Report Number(s):
EPRI-TR-100743
Country of Publication:
United States
Language:
English