Ripple feedback for the resonant-filter unity-power-factor rectifier
Journal Article
·
· IEEE Transactions on Power Electronics (Institute of Electrical and Electronics Engineers); (United States)
- GE Transportation Systems, General Electric Co., Erie, PA (US)
- Dept. of Electrical Engineering, Univ. of Toledo, Toledo, OH (US)
An unusual bucklike unity-power-factor rectifier with a resonant load-balancing network permits current-limited operation down to zero output voltage in a single-stage-topology. However, this rectifier has been found to be sensitive to ac-line voltage distortion and is potentially unstable with realistic values of ac-line impedance. In this paper, a new ripple feedback is proposed that solves both problems. A large-signal time-varying analysis is given along with incremental, quasi-static, and low-frequency approximations. Experimental verification is provided by a 500-W 50-kHz rectifier operating from the 120-V 60-Hz distribution system.
- OSTI ID:
- 7278811
- Journal Information:
- IEEE Transactions on Power Electronics (Institute of Electrical and Electronics Engineers); (United States), Vol. 7:3; ISSN 0885-8993
- Country of Publication:
- United States
- Language:
- English
Similar Records
High performance ripple feedback for the buck unity-power-factor rectifier
Fast controller for a unity-power-factor PWM rectifier
Design and development of a 4-kW/2-kHz dc-isolated power conditioner for utility-interactive photovoltaic applications
Journal Article
·
Wed Mar 01 00:00:00 EST 1995
· IEEE Transactions on Power Electronics
·
OSTI ID:7278811
Fast controller for a unity-power-factor PWM rectifier
Journal Article
·
Mon Jan 01 00:00:00 EST 1996
· IEEE Transactions on Power Electronics
·
OSTI ID:7278811
+1 more
Design and development of a 4-kW/2-kHz dc-isolated power conditioner for utility-interactive photovoltaic applications
Technical Report
·
Tue Sep 01 00:00:00 EDT 1987
·
OSTI ID:7278811
+1 more
Related Subjects
42 ENGINEERING
24 POWER TRANSMISSION AND DISTRIBUTION
POWER DISTRIBUTION SYSTEMS
RECTIFIERS
FEEDBACK
AC SYSTEMS
ELECTRIC IMPEDANCE
FLUCTUATIONS
KHZ RANGE 01-100
OPERATION
POWER FACTOR
RESONANCE
SENSITIVITY
ELECTRICAL EQUIPMENT
EQUIPMENT
FREQUENCY RANGE
IMPEDANCE
KHZ RANGE
POWER SYSTEMS
VARIATIONS
426000* - Engineering- Components
Electron Devices & Circuits- (1990-)
240200 - Power System Networks
Transmission & Distribution- (1990-)
24 POWER TRANSMISSION AND DISTRIBUTION
POWER DISTRIBUTION SYSTEMS
RECTIFIERS
FEEDBACK
AC SYSTEMS
ELECTRIC IMPEDANCE
FLUCTUATIONS
KHZ RANGE 01-100
OPERATION
POWER FACTOR
RESONANCE
SENSITIVITY
ELECTRICAL EQUIPMENT
EQUIPMENT
FREQUENCY RANGE
IMPEDANCE
KHZ RANGE
POWER SYSTEMS
VARIATIONS
426000* - Engineering- Components
Electron Devices & Circuits- (1990-)
240200 - Power System Networks
Transmission & Distribution- (1990-)