The data presented summarize experience in obtaining plutonium and americium isotopic data using two systems: a 70 cc Ge(Li) system with 1.8 keV resolution at 1332 keV for acquisition of spectra up to 700 keV gamma-ray energy and a 1 cc planar system with 600 eV resolution at 122 keV for the acquisition of spectra up to 220 keV. Plutonium samples include ash samples with plutonium-240 concentrations of 9 to 20 percent; plutonium metal samples 6 percent--plutonium-240; ZPPR fuel pins; and various waste categories of 6 percent--plutonium-240 material. Nondestructive isotopic ratios obtained by gamma-ray spectroscopy are compared to chemical data obtained from these samples.