Circumferential arrays used for UT endoscopy on heat exchanger tubes
Book
·
OSTI ID:72604
- Fraunhofer-Einrichtung fuer Akustische Diagnose und Qualitaetssicherung des IzfP, Dresden (Germany)
- Fraunhofer-Inst. fuer zerstoerungsfreie Pruefverfahren, Saarbruecken (Germany)
- Fraunhofer-Einrichtung fuer Festkoerperphysik und Schichttechnologie, Dresden (Germany)
Corrosion damage on steam generator (SG) heat exchanger tubes of nuclear power plants has repeatedly been the cause of limitations in availability and steam generator replacements. The objective here is to develop an ultrasonic testing (UT) method which enables damage phenomena on SG heat exchanger tubes to be determined and assessed. The method is based on the use of miniaturized ultrasonic array probes of piezoelectric composite materials whose characteristic impedance can be well matched to the load medium (water) and therefore guarantees a high signal efficiency with a good time resolution.
- OSTI ID:
- 72604
- Report Number(s):
- CONF-931061--; ISBN 0-87170-506-0
- Country of Publication:
- United States
- Language:
- English
Similar Records
Depth size technology of ultrasonic testing in steam generator tubes
On the influence of manufacturing practices on the SCC behavior of Alloy 690 steam generator tubing
Circumferential cracking in steam generator tubes repaired by mechanical sleeving
Book
·
Sun Sep 01 00:00:00 EDT 1996
·
OSTI ID:277833
On the influence of manufacturing practices on the SCC behavior of Alloy 690 steam generator tubing
Book
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:409743
Circumferential cracking in steam generator tubes repaired by mechanical sleeving
Book
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:203798