Horizontal flow drilling requires focus on well control
- RBOP Oil Tools International Inc., Houston, TX (United States)
Horizontal wells drilled underbalanced or while flowing must have surface equipment and a blow-out preventer stack specially designed for circulating operations. Functional well control methods for drilling horizontal wells have been developed in specific regions worldwide. Special safety equipment and procedures, however, are still required in most horizontal development applications. The challenge for horizontal drilling development and underbalanced drilling is to overcome the obstacles of government regulation, reduce pollution dangers, and improve personnel and equipment safety. Well control techniques tailored to the demands of each field can help overcome these challenges. Several well control elements must be addressed carefully on each horizontal well: drilling fluid requirements, well control procedures and equipment, and surface equipment and special considerations for handling hydrocarbons produced while drilling. The paper discusses each of these elements for underbalanced horizontal drilling.
- OSTI ID:
- 7260115
- Journal Information:
- Oil and Gas Journal; (United States), Journal Name: Oil and Gas Journal; (United States) Vol. 92:24; ISSN OIGJAV; ISSN 0030-1388
- Country of Publication:
- United States
- Language:
- English
Similar Records
Underbalanced drilling guidelines improve safety, efficiency
Horizontal underbalanced drilling of gas wells with coiled tubing