TFTR microwave reflectometer (abstract)

Journal Article · · Review of Scientific Instruments; (United States)
DOI:https://doi.org/10.1063/1.1143653· OSTI ID:7259319
; ; ; ;  [1]
  1. Princeton University, Princeton, New Jersey 08543 (United States)
A microwave reflectometer is in operation on TFTR for the measurement of density fluctuations. The system operates in the {ital X} mode and comprises three channels with fixed frequencies of 140, 132, and 125 GHz, and one with stepped frequency of 111--123 GHz. All channels use solid state Gunn oscillators and a heterodyne detection scheme. The system is located outside of the TFTR test cell with the power conveyed to the tokamak vessel by low-loss corrugated waveguides and remotely controlled parabolic mirrors. Preliminary results indicate that the level of density fluctuations with {ital k}{sub {perpendicular}} {lt}1 cm{sup {minus}1} is very small in the central region of Ohmic plasmas ({ital {tilde n}}/{ital n}{lt}10{sup {minus}3}), and that it increases monotonically with minor radius to values of {approx}10{sup {minus}2} at {ital r}/{ital a}=0.9. This work supported by U.S. Department of Energy Contract No. DE-AC02-76-CHO-3073.