High resolution monochromator for the VUV radiation from the DORIS storage ring
Journal Article
·
· Appl. Opt.; (United States)
The unique properties of the DORIS storage ring at DESY as a synchroton radiation source are exploited for high resolution spectroscopy in the vacuum ultraviolet. We describe a new experimental set up with a 3-m normal incidence monochromator for wavelengths between 3000 A and 300 A (4 < or = h..omega.. < or = 40 eV) using a vertical dispersion plane. The storage ring provides a light flux intense and stable enough for rapid photoelectrical scanning of the spectra with a resolution of 0.03 A in first order. (AIP)
- Research Organization:
- Universitat Munchen Sektion Physik, 8 Munchen 40, F.R.G.
- OSTI ID:
- 7251377
- Journal Information:
- Appl. Opt.; (United States), Vol. 60:4
- Country of Publication:
- United States
- Language:
- English
Similar Records
DESY II, a new injector for the DESY storage rings PETRA and DORIS II
A new generation of atomic collision experiments at storage rings
Grazing-incidence monochromator for the 15--800 A wavelength range at the storage ring VEPP-2M
Journal Article
·
Mon Aug 01 00:00:00 EDT 1983
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:7251377
A new generation of atomic collision experiments at storage rings
Journal Article
·
Wed May 01 00:00:00 EDT 1996
· Bulletin of the American Physical Society
·
OSTI ID:7251377
Grazing-incidence monochromator for the 15--800 A wavelength range at the storage ring VEPP-2M
Journal Article
·
Sat Jul 01 00:00:00 EDT 1989
· Rev. Sci. Instrum.; (United States)
·
OSTI ID:7251377
+6 more