The use of energy management and control systems for retrofit performance monitoring in the LoanSTAR program
- Lawrence Berkeley Lab., CA (United States)
- Texas A and M Univ., College Station, TX (United States). Energy Systems Lab.
Monitoring of building energy consumption, operation, and weather variables are important parts of retrofit evaluation projects. However, effective monitoring can be quite expensive. In this report, we investigate the feasibility of using a building's existing energy management and control system (EMCS) for gathering some or all of this required data, rather than installing dedicated data-logging equipment. Three case studies in the Texas LoanSTAR retrofit monitoring program were used to explore the current applicability of existing EMCSs for monitoring, and to identify areas requiring additional development It was found that data could be retrieved in each case; without installing any additional hardware or software in two of the three sites, and with the addition of only a few sensors and a minor software modification in the third. However, the process of using the EMCS for monitoring was inconvenient in several respects. It was determined that the process could be greatly simplified if EMCS manufacturers ensured that their software averaged data over an hourly interval and reliably reported them at the end of each hour, used concise and consistent formats for requesting and reporting the data, and provided a simple means of displaying or transmitting the data.
- Research Organization:
- Lawrence Berkeley Lab., CA (United States)
- Sponsoring Organization:
- DOE; USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 7243136
- Report Number(s):
- LBL-31144; ON: DE93001601
- Country of Publication:
- United States
- Language:
- English
Similar Records
The use of energy management and control systems for retrofit performance monitoring in the LoanSTAR program. Final report
Use of energy management and control systems for performance monitoring of retrofit projects
The use of EMCS in building monitoring: Experience from energy edge and LoanSTAR Programs
Technical Report
·
Tue Mar 31 23:00:00 EST 1992
·
OSTI ID:10178976
Use of energy management and control systems for performance monitoring of retrofit projects
Technical Report
·
Sun Dec 31 23:00:00 EST 1989
·
OSTI ID:6262541
The use of EMCS in building monitoring: Experience from energy edge and LoanSTAR Programs
Conference
·
Wed Mar 31 23:00:00 EST 1993
·
OSTI ID:105861
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320105* -- Energy Conservation
Consumption
& Utilization-- Building Services-- (1987-)
CONTROL SYSTEMS
DATA PROCESSING
DEVELOPED COUNTRIES
DOCUMENT TYPES
ENERGY CONSERVATION
ENERGY CONSUMPTION
EVALUATION
FEDERAL REGION VI
FINANCIAL ASSISTANCE
FINANCIAL INCENTIVES
FINANCING
MONITORING
NORTH AMERICA
PROCESSING
PROGRESS REPORT
RETROFITTING
TEMPERATURE MEASUREMENT
TEXAS
USA
WEATHER
320105* -- Energy Conservation
Consumption
& Utilization-- Building Services-- (1987-)
CONTROL SYSTEMS
DATA PROCESSING
DEVELOPED COUNTRIES
DOCUMENT TYPES
ENERGY CONSERVATION
ENERGY CONSUMPTION
EVALUATION
FEDERAL REGION VI
FINANCIAL ASSISTANCE
FINANCIAL INCENTIVES
FINANCING
MONITORING
NORTH AMERICA
PROCESSING
PROGRESS REPORT
RETROFITTING
TEMPERATURE MEASUREMENT
TEXAS
USA
WEATHER