Spall Strength Measurements of Concrete for Varying Aggregate Sizes
- Sandia National Laboratories
Controlled impact experiments have been performed to determine the spall strength of four different concrete compositions. The four concrete compositions are identified as, `SAC-5, CSPC', ("3/4") large, and ("3/8") small, Aggregate. They differ primarily in aggregate size but with average densities varying by less than five percent. Wave profiles from sixteen experiments, with shock amplitudes of 0.07 to 0.55 GPa, concentrate primarily within the elastic regime. Free-surface particle velocity measurements indicate consistent pullback signals in the release profiles, denoting average span strength of approximately 40 MPa. It is the purpose of this paper to present spall measurements under uniaxial strain loading. Notwithstanding considerable wave structure that is a unique characteristic to the heterogeneous nature of the scaled concrete, the spall amplitudes appear reproducible and consistent over the pressure range reported in this study.
- Research Organization:
- Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 7237
- Report Number(s):
- SAND99-1128C; ON: DE00007237
- Country of Publication:
- United States
- Language:
- English
Similar Records
Elastic shock response and spall strength of concrete
Spall behavior of aluminum with varying microstructures