VAV/bypass filtration system controls VOCs, particulates
Journal Article
·
· Heating, Piping and Air Conditioning; (United States)
OSTI ID:7234051
- Meckler Engineers Group, Encino, CA (United States)
This article describes how a proprietary demand control ventilation system equipped with an IAQ sensor helps provide acceptable air quality, comfort, and cost effectiveness, especially with VAV systems. Properly implemented demand control ventilation (DCV) strategies can provide the opportunity to maintain acceptable indoor air quality (IAQ) in accordance with ASHRAE Standard 62-1989 while offering significant energy savings. This article will introduce a proprietary DCV system already equipped with an IAQ sensor that directly measures the concentration of VOCs in an occupied space and accordingly modulates supply air rates to provide acceptable IAQ, comfort, and cost effectiveness, especially for variable air volume (VAV) systems. In addition, system filter and bypass filter selection criteria for both retrofit and new building applications will be outlined.
- OSTI ID:
- 7234051
- Journal Information:
- Heating, Piping and Air Conditioning; (United States), Journal Name: Heating, Piping and Air Conditioning; (United States) Vol. 66:3; ISSN HPAOAM; ISSN 0017-940X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Carbon dioxide prediction model for VAV system part-load evaluation
ASHRAE Standard 62R: A simple method of compliance
Biomedical laboratory uses VAV fume hoods and heat recovery to save fuel costs
Journal Article
·
Thu Dec 31 23:00:00 EST 1992
· Heating, Piping and Air Conditioning; (United States)
·
OSTI ID:5944719
ASHRAE Standard 62R: A simple method of compliance
Journal Article
·
Wed Oct 01 00:00:00 EDT 1997
· Heating, Piping and Air Conditioning
·
OSTI ID:563907
Biomedical laboratory uses VAV fume hoods and heat recovery to save fuel costs
Journal Article
·
Mon Feb 28 23:00:00 EST 1994
· ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States)
·
OSTI ID:7176410
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320107* -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
AIR POLLUTION
AIR QUALITY
BUILDINGS
ENVIRONMENTAL QUALITY
EQUIPMENT
INDOOR AIR POLLUTION
MATTER
ORGANIC COMPOUNDS
POLLUTION
POLLUTION CONTROL EQUIPMENT
VOLATILE MATTER
320107* -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
AIR POLLUTION
AIR QUALITY
BUILDINGS
ENVIRONMENTAL QUALITY
EQUIPMENT
INDOOR AIR POLLUTION
MATTER
ORGANIC COMPOUNDS
POLLUTION
POLLUTION CONTROL EQUIPMENT
VOLATILE MATTER